Cito Autosampler for S-flow IV

Autosampler for automated Houillon viscosity testing
Cito offers high-throughput sampling, eliminating any errors that could be caused by incorrect injection and frees up the operator to attend to other duties. It works fully autonomously, requiring no operator presence.
Autosampler
Excellent Repeatability
High throughput
Services up to 2 systems
Highly accurate

Contact us to discuss the specifics of your tailor-made Cito autosampler for your Houillon viscometer

Omnitek is a viscometer manufacturer based in The Netherlands and develops Houillon viscometers with an optional robotic arm that automates the injection procedure in the methodology, choose the configuration that best suits your lab and your sample vial. Request an informative brochure or experience how easy can be measuring Houillon viscosity with Cito through our online demo facilities. Would you like our advice, or do you have questions about the use of our Cito Autosampler? Please, contact us by calling +31 (0)182 - 302990 or send an email to info@omnitek.nl to ask for our assistance. We manufacture each system according to the requirements of our clients.
Maximum throughput and ease of use with very low sample and solvent consumption
 

The latest generation of new S-flow builds on the strong foundation of its predecessors to offer the ultimate in automatic viscosity testing of Newtonian samples such as petroleum products. The system offers all the tried and tested advantages of a Houillon-type tube design such as short process times, small sample volume and low solvent consumption, but now also includes an optional autosampler to allow for fully unattended operation. All controlled from a central user interface that takes care of result storage, autosampler control, VI calculations and much more. It complies fully with ASTM D7279 and as such, provides full correlation to ASTM D445. It is the ideal system for used oil analysis labs that need to test a wide range of lubricant viscosities.

The new S-flow IV+ consists of a 2 bath system with 2 tubes in each bath, providing a total of 4 tubes. The baths were designed to work independently, making it possible to use both baths at the same temperature, or at different temperature, ranging from 20°C to 120°C. Other options include dual solvent cleaning and integrated duplo testing which obtains 2 flow time determinations with only 1 sample injection.

All measurement parameters, such as warmup times and cleaning parameters can be set through the high resolution 12” touchscreen or with optional PC software. The diagnostic system alerts the operator to possible issues such as empty solvent supply tanks, full waste bottles and other potential issues. The optional auto-sampler is fully modular and in-field upgradeable, meaning you can purchase the analyser first and then upgrade to auto-sampling when the need arises.

Features
S-flow IV+ 
Number of baths 2
Viscometers per bath 2
Standard methods Compliant with ASTM D7279, D2270
Correlation with ASTM D445
Built-in VI calculation Yes
Measuring range 0.3 - 3,000 mm2/s @40°C
Temperature range  20 – 120°C *
Temperature stability Better than ±0.02°C
Timer resolution 0.001 s
Sample volume 0.3 – 1.0 ml
Solvent consumption 2 – 3 ml per cycle
Samples per hour  Up to 80 samples per hour **
Viscometer type Houillon
Sensor type Optical, self-calibrating
Time measurement Automatic
Solvent injection Automatic
Advanced PC software option Yes
Dual solvent option Yes
Duplo measurement option Yes
External cooling system option Yes
Air compressor Yes
Silicone oil option Yes
Integrated cleaning pump Yes
Warmup prior to measuring Yes
Touchscreen 12” capacitive
Optional autosampler Yes
Dimensions 40 x 58 x 66 cm (w x d x h)
Weight 52 kg
Data export USB storage device
Power requirement

950 W; 115/240V - 50/60Hz 

* For temperatures around ambient, an external chiller is required
** Measurements per hour; depends on viscosity, tube, temperature and solvents 

 
Optional accessories & upgrades

Following items are optional accessories and upgrades to the instrument.

 
Dual solvent cleaning

A suitable solvent used for cleaning should have the following two main characteristics:

  •  It should be able to dissolve the sample that was tested, i.e. clean the tube completely
  •  It should evaporate quickly enough at the bath temperature so that the tube is fully dry after cleaning

If the solvent used does have the ability to dissolve the sample, but does not evaporate quickly enough, a second solvent can be used to rinse out the first solvent, as well as dry the tube. Usually, low boiling solvents are used for this purpose, such as Acetone or MEK. 

 
Cooling circulator

For measurements close to ambient (± 8°C), an additional cooling circulator is required to create sufficient offset for the temperature control unit. Each bath is fitted with a cooling spiral, to which an external cooling circulator can be easily connected. Complete with tubing and fittings. 

 

Single                    Duplo

Afbeeldingproduct2.png

 
Duplo measurement tubes

The optional duplo measurement configuration adds another array of optical detections to the instrument, bringing the total number of detection points to three per tube instead of two.  Together with adapted S-flow IV tubes, which are fitted with two measuring trajectories, this enables the S-flow IV+ to perform duplo measurements with a single sample injection, increasing productivity, saving even more on solvent consumption and run time.

 
Compressor

Omnitek S-flow IV+ operate on clean and dry 5 bar @ 5 l/min of compressed air. A suitable compressor can be supply from Omnitek if no compressed air is available. 

 
Positive - displacement pipette

Air-displacement pipette is supplied with S-flow IV+ as a standard. It is recommended to use positive displacement pipette especially at higher viscosities (300 mm2/s and above) to avoid operator errors and for more accurate and repeatable injections.  

 
Software

Omnitek S-flow IV+ utilizes advanced and easy to use multi-lingual software, it can be operated directly from the touchscreen, and both calibration and viscosity measurements can be performed without PC or software. However, to have more control, dedicated optional software is available, which can be used to control multiple systems.

 
PC

A PC system can be sourced locally or through Omnitek. Omnitek supplies the latest model entry level laptop or, if required, desktop. When sourcing locally, make sure the operating system is Windows 7 or later and that the PC/Laptop has 1 free USB port per instrument. 

 
Printer

Any kind of printer can be used if instrument is connected to a PC via software. A printer can be sourced locally or through Omnitek. Omnitek supplies the latest model entry level laser printer.

 
Autosampler operation

Omnitek offers autosampler operation for S-flow IV+. It is ideal for customers that run large numbers of samples and want to automate their sampling process. As each laboratory will have its own requirements, automation is a highly customized product which requires elaborate preparation. The autosampler stands out for being a modular high speed autosampler, it can be in-field upgradeable, services up to 2 S-flow IV+ instruments (8 tubes), processes 25-40 samples per hour and it is customizable to allow different sample cups and racks.

Please contact us for specific solutions to your sampling needs. 

 
Thermometers

The customer should have a DCT shaft diameter < 3mm. The recommended thermometers that can be supplied are the modern digital contact thermometers (DCT), used at multiple temperatures

Features
  • Applicable for fuels, base oils, formulated oils, and petroleum products as well as water-based fluids
  • Compliant with requirements for ASTM D7279, ASTM 2270 and correlation to ASTM D445
  • High throughput: up to 80 samples per hour under ideal operation conditions
  • Very easy to use and maintain
  • Small sample volume: 0.3 – 1.0 ml
  • Low solvent consumption: 2 – 3 ml per sample.
  • Extremely accurate temperature control and flow-time measurement independent of fluid type
  • Automatic calibration of the optic amplifiers
  • Automatic flow time measurement with ultraprecise meniscus detection
  • Fully automatic cleaning and drying
  • Fast & easy tube replacement (tubes are not connected to optical sensors)
  • No need to drain bath during tube replacement.
  • Single or dual solvent injection (optional)
  • Measurement at 2 temperatures in 1 system simultaneously
  • Integrated VI calculations
  • Stand-alone unit. No PC required.
  • Chemically resistant to allow for all common solvents
  • Bath scheduler to turn baths on/off on preset times
  • Bath temperature graphs on screen
  • Bath backlight. It improves visibility of viscometer tubes and sensors
  • User Access Control
  • Duplo measurement capability
  • Integrated back flushing
  • Optional autosampler

This product is compliant with the following test methods:

  •  ASTM D7279 
  •  ASTM D2270

This product is correlating with the following test method:

  •  ASTM D445
Industries
Petroleum Based Samples
Other Sample Types

Refineries

Lubricating Oils

Printer ink

Terminals (Fuel Distribution)

Additives

Gelatins
Lubricant Manufacturers Base Stocks  

Additive Manufacturers

Industrial Oils

 

Condition Monitoring Labs

Transmission Oils

 

Third Party Testing Labs

Hydraulic Fluids

 

Research & Development Labs

Used Oils

 

Quality Control Labs

Waste Oils

 

Military Labs

Crude Oils

 

Power Plants

Fuel Oils

 

Mines

Gasoline 

 

Customs

Diesel

 

Universities

Bio Fuels

 

Automotive

Marine Fuels

 

Chemical Plants

 

 

Iron & Steel

   

Textile

   

Aviation

   

Railways

   
Highways    

For other fluids / solutions please send your inquire